Summary for Test 2026-04-24-6-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001108 DEA: 061A0904 EFIS: 0620000065 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-168-49.1/49.5 |
| Award Date | 12/19/2025 |
| Closeout Date | Not set |
| Work Description | SHAVER LAKE VIADUCT. CONSTRUCT SIDEHILL VIADUCT STRUCTURE. |
| Location Description | FRESNO COUNTY NEAR SHAVER LAKE FROM 1.3 MILES EAST OF DALTON AVENUE TO 0.2 MILE WEST OF HUNTINGTON LAKE ROAD. |
| QA Service Level | 1 (Verified on 03/25/2025) |
Sample Information
| Sample Taken Date | 04/24/2026 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/30/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #5x 3'-2", ASTM A706 Gr. 60 |
| The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Alexis | Last name of sampler or witnessed by | Millan |
| Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 9097569960 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar Cascade | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-064-26 | Structure unique identifier | |
| Structure name | Bid Item | 3944778 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 075026 |
| Hoop Manufacturer Lot Number(s) | 1-2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-04-24-6
DIME Test ID: 2026-04-24-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-05-14
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 05/14/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 5 | 0.31 | 29860 | 96500 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 5 | 0.31 | 29340 | 94500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 5 | 0.31 | 28830 | 93000 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 5 | 0.31 | 28790 | 93000 | ok necking | Kleinfelder |
| 5 | 1 | 2 | 5 | 0.31 | 28370 | 91500 | affected zone | Kleinfelder |
| 6 | 2 | 2 | 5 | 0.31 | 27870 | 90000 | ok necking | Kleinfelder |
| 7 | 3 | 2 | 5 | 0.31 | 27840 | 90000 | ok necking | Kleinfelder |
| 8 | 4 | 2 | 5 | 0.31 | 27780 | 89500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/14/2026 ✔