Summary for Test 2026-04-20-25-10
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1001098 DEA: 081P0804 EFIS: 0823000089 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-7.0/44.5 |
| Award Date | 06/03/2025 |
| Closeout Date | Not set |
| Work Description | FURNISH & PLACE POLYESTER CONCRETE OVERLAY, JOINT SEAL, HMA (BRIDGE). |
| Location Description | RIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM VEILE AVENUE UNDERCROSSING IN BEAUMONT TO MONTEREY AVENUE OVERCROSSING AT THOUSAND PALMS |
| QA Service Level | 1 (Verified on 04/07/2025) |
Sample Information
| Sample Taken Date | 04/20/2026 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2026 |
| Sample type | Verification | A brief description of the sample | JMF 1/2" HMA-A-SP R25 0.3% EVO |
| The quantity of what the sample constitutes | 9 bags Virgin Bin Agg, 3 bags comb Agg | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | MM | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0201A-26 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Ingevity/ Valero/ Coachella Valley/ MM-Coachella | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0084 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | belt cut at martin marietta, coachella | |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 1/2 inch |
| The concrete mix design number | 41217195WM | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-04-20-25
DIME Test ID: 2026-04-20-25-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-07-07
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Amir Sarder
Date of test: 05/01/2026
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 98 % | ||||||
| 86 % | ||||||
| 67 % | ||||||
| 56 % | ||||||
| 41 % | ||||||
| 28 % | ||||||
| 18 % | ||||||
| 11 % | ||||||
| 6.6 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Combined Aggregate Gradation W/ RAP Gradation Correction
Test was verified on 7/7/2026 ✔