Summary for Test 2026-04-01-72-6
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994366 DEA: 044J9104 EFIS: 0416000010 |
|---|---|
| DIST-CO-RTE-PM | 04-SCL-87-0.0/6.1 |
| Award Date | 04/19/2023 |
| Closeout Date | Not set |
| Work Description | Cold plane AC, paving with RHMA, upgrade median CB and curb ramp. |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SANTA CLARA COUNTY IN SAN JOSE FROM ROUTE 85/87 SEPARATION TO 0.1 MILE NORTH OF JULIAN STREET UNDERCROSSING. |
| QA Service Level | 1 (Verified on 04/05/2023) |
Sample Information
| Sample Taken Date | 04/01/2026 | Sample Unique Key | 72 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/21/2026 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
| The quantity of what the sample constitutes | 200 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | EDWARD | Last name of sampler or witnessed by | LEACH |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 10936000 | Nut Mfg. Lot Number(s) | N/A |
| Washer Mfg. Lot Number(s) | N/A | Bolt Specification | A325 |
| Bolt Length(s) | 4" | Nut Specification | N/A |
| Washer Specification | N/A | Finish | Galv |
| Diameter/Size | 1-1/8" x 4" | Bolt Mfg. Lot Number | M6145 |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
| Washer Inner Diameter(s) | 0 |
Test Details
DIME Sample ID: 2026-04-01-72
DIME Test ID: 2026-04-01-72-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-05-19
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 05/14/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | E284U1 | 1.125 | 120100 | 0 | 0 | NA | WSP |
| 2 | 1B | E284U1 | 1.125 | 120325 | 0 | 0 | NA | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/19/2026 ✔