Summary for Test 2026-05-04-43-5
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 993454 DEA: 040K8004 EFIS: 0416000141 COOP: 042892 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-13.7 |
| Award Date | 02/05/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT ROUNDABOUT, CURB RAMPS AND SW, SIGNAL AND LIGHTING SYSTEMS. |
| Location Description | MARIN COUNTY IN SAN RAFAEL AT FREITAS PARKWAY OVERCROSSING |
| QA Service Level | 1 (Verified on 12/10/2021) |
Sample Information
| Sample Taken Date | 05/04/2026 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/04/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
| The quantity of what the sample constitutes | 4 Boxes 1 Bag | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jose Leon | Last name of sampler or witnessed by | Amparan |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Dutra San Rafael | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-05-04-43
DIME Test ID: 2026-05-04-43-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-05-13
Test Results
Does this test use 1/4 sieve?: Yes
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 05/04/2026
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1884.6 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.2 % | 100 % | ||||
| 254.7 grams | -2.6 % | 84 % | ||||
| 487.0 grams | -7.2 % | 67 % | ||||
| 1137.1 grams | -6.1 % | 34 % | ||||
| 1137.1 grams | -6.1 % | 34 % | ||||
| 1420.2 grams | -4.8 % | 20 % | ||||
| 1576.6 grams | -3.7 % | 13 % | ||||
| 1671.8 grams | -2.9 % | 8 % | ||||
| 1751.6 grams | -2.1 % | 5 % | ||||
| 1823.0 grams | -1.3 % | 2 % | ||||
| 1874.5 grams | -0.5 % | 0.0 % | ||||
| 1875.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/13/2026 ✔