Summary for Test 2026-05-12-30-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 993454
DEA: 040K8004
EFIS: 0416000141
COOP: 042892
DIST-CO-RTE-PM04-MRN-101-13.7
Award Date02/05/2025
Closeout DateNot set
Work DescriptionCONSTRUCT ROUNDABOUT, CURB RAMPS AND SW, SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMARIN COUNTY IN SAN RAFAEL AT FREITAS PARKWAY OVERCROSSING
QA Service Level1 (Verified on 12/10/2021)

Sample Information

Sample Taken Date05/12/2026 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing05/12/2026 Sample typeQuality Assurance
A brief description of the samplecompaction The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byJose Leon
Last name of sampler or witnessed byAmparan Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUS 101/Manuel T Freitas Parkway (MFP) Interchange in the City of San Rafael
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Jobsite
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedJob Site Roadway Sidewalk
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-05-12-30
DIME Test ID: 2026-05-12-30-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-05-13

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Jose Leon Amparan
Date of test: 05/12/2026
Gage No.: 691
Test No.: no data
Nuclear By: LA
Non-Bias Plan No.: 2
Depth: 8
Material No.: no data
Material Type: class 2 AB
Impact By: LA
Standard Count Density: 30792 g/cc
Count or Density 1: 20650 g/cc
Count or Density 2: 19226 g/cc
Count or Density 3: 20134 g/cc
Standard Count Moisture: 8501 g/cc
Moisture Count 1: 1647 g/cc
Moisture Count 2: 1734 g/cc
Moisture Count 3: 1832 g/cc
Sum of Count or Density: 60010 g/cc
Average of Count or Density: 20003.33 g/cc
Sum of Moisture Count: 5213 g/cc
Average of Moisture Count: 1737.67 g/cc
Calculated Percent Relative Compaction: 98 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): Passed

Test was verified on 5/13/2026 ✔