Summary for Test 2026-05-05-35-8

Test performed: AASHTO T308-25
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 1002191
DEA: 11432934
EFIS: 1126000018
DIST-CO-RTE-PM11-UNKNOWN--
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/05/2026 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing05/05/2026 Sample typeVerification
A brief description of the sampleJMFR The quantity of what the sample constitutes12 boxes
From where was the sample collectedSupplier First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byCordero Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAPI Gateway
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1-1/2 inch Lot number
Sublot number HMA Mix Number16
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder SupplierValero
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2026-05-05-35
DIME Test ID: 2026-05-05-35-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-05

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 05/14/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4024.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 8042.4 g
Mass of HMA Sample prior to ignition: 4017.9 g
Mass Loss: 156.0 g
Mass of aggregate remaining after ignition: 3861.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 3.81 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 3.80 Tested 3.81 %

Test was verified on 6/5/2026 ✔

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.