Summary for Test 2026-04-15-51-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001902 DEA: 061H6704 EFIS: 0625000240 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-190-26.65 |
| Award Date | 07/28/2026 |
| Closeout Date | Not set |
| Work Description | Replace exiting bridge rail on EB direction of SR 190, demo and reconstruct overhang, remove existing AC overlay, deck overhang strengthening at bridge rail, poly conc overlay, install new ST-75 barrier rail. |
| Location Description | Tule River Bridge (BR #46-0187). |
| QA Service Level | 1 (Verified on 01/08/2026) |
Sample Information
| Sample Taken Date | 04/15/2026 | Sample Unique Key | 51 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1" x 19" F1554 Grade 105 Rod |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Alvarez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Atwater Metal Fabrication | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S91-071-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | 1000128077 Bolt 21002280 Nut 190154844 Washer | Nut Mfg. Lot Number(s) | E591W1 |
| Washer Mfg. Lot Number(s) | 0925-778 | Bolt Specification | F1554 Grade 105 |
| Bolt Length(s) | 19" | Nut Specification | A563 Grade DH |
| Washer Specification | F436 Type 1 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 100012807740 |
| Rocap Test Requirement(s) | 0 | Lubricant Requirements(s) | 0 |
| Washer Inner Diameter(s) | 0 |
Test Details
DIME Sample ID: 2026-04-15-51
DIME Test ID: 2026-04-15-51-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-05-13
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 05/12/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 21002280 | 1 | 90900 | 0 | 0 | Nut Proof Load | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/13/2026 ✔