Summary for Test 2026-04-08-28-1
Test performed: ASTM A416-18Project Information
| Project Identifiers | Project ID: 1001941 DEA: 040V5104 EFIS: 0426000263 COOP: NONE |
|---|---|
| DIST-CO-RTE-PM | 04-SON--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 02/04/2026) |
Sample Information
| Sample Taken Date | 04/08/2026 | Sample Unique Key | 28 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 0.6" Prestressing Strand |
| The quantity of what the sample constitutes | 1 Pack | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Vasquez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S337115-2 | Number of Coils | |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0509826 | Mfg. Lot Number(s) | S337115-2 |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2026-04-08-28
DIME Test ID: 2026-04-08-28-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-05-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 05/12/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0509826 | S337115-2 | 0.217 | 59610 | 56980 | 28.1 | 5.86 | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/19/2026 ✔