Summary for Test 2026-04-06-17-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1001194
DEA: 051H4404
EFIS: 0516000074
DIST-CO-RTE-PM05-SB,SLO-1-50.3/50.6,0.0/0.3
Award Date09/30/2025
Closeout DateNot set
Work DescriptionSANTA MARIA RIVER BRIDGE (REPLACE).
Location DescriptionSANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE
QA Service Level1 (Verified on 06/02/2025)

Sample Information

Sample Taken Date04/06/2026 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/08/2026
Sample typeQuality Assurance A brief description of the sample.6 PC STRAND
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byMike Last name of sampler or witnessed byVasquez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Products Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0507026, S0510326, S0511126, S0511026 Mfg. Lot Number(s)S337096-2, S337098-5, S337099-1, S381155-8
Manufacturer(s)Sumiden Wire Products Corporation

Test Details

DIME Sample ID: 2026-04-06-17
DIME Test ID: 2026-04-06-17-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-05-19

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 05/12/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0507026S337096-20.217588705620029.95.17Atlas
2S0510326S337098-50.217589505551027.86.46Atlas
3S0511126S337099-10.217592805573028.86.89Atlas
4S0511026S381155-80.217593705733028.85.80Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/19/2026