Summary for Test 2026-05-05-36-15
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 1002191 DEA: 11432934 EFIS: 1126000018 |
|---|---|
| DIST-CO-RTE-PM | 11-UNKNOWN-- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/05/2026 | Sample Unique Key | 36 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/05/2026 |
| Sample type | Verification | A brief description of the sample | JMFR |
| The quantity of what the sample constitutes | 5 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | See Mix |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 16 |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2026-05-12: HMA Aggregates (Size 1-1/2"): Type A HMA - Batch Plant - Sieve Analysis Without RAP | 2 | 2026-05-05-36-15 |
Test Details
DIME Sample ID: 2026-05-05-36
DIME Test ID: 2026-05-05-36-15
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-05-18
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 05/14/2026
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 3631.0 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 1485.0 grams | 59 % | |||||
| 3432.0 grams | 5 % | |||||
| 3626.0 grams | 0 % | |||||
| 7 grams | ||||||
| 1.2 grams | 0 % | |||||
| 1.8 grams | 0 % | |||||
| 2.2 grams | 0 % | |||||
| 2.2 grams | 0 % | |||||
| 3.7 grams | 0 % | |||||
| 4.3 grams | 0 % | |||||
| 4.3 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): N/A
1/2"
Test was verified on 5/18/2026 ✔