Summary for Test 2026-04-28-34-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000365 DEA: 033H9014 EFIS: 0323000075 |
|---|---|
| DIST-CO-RTE-PM | 03-SOL,YOL-50,80,113-Var |
| Award Date | 09/27/2024 |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, SIGN STRUCTURE, CAMERA SYSTEMS, & FO CABLE SYSTEMS. |
| Location Description | SOLANO AND YOLO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/17/2024) |
Sample Information
| Sample Taken Date | 04/28/2026 | Sample Unique Key | 34 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/30/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4 RHMA-G | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Luis |
| Last name of sampler or witnessed by | Magana | Title of sampler | QA Tech |
| Telephone number of sampler | 2092250104 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | De Silva Gates - Marysville | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 10 | HMA Mix Number | MD 6617 |
| Binder content (%) | 7.5 | Virgin binder PG | PG 64-16 |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 0 | WMA Additives | |
| Antistrip type | Evotherm M1 0.25% (BWB) |
Test Details
DIME Sample ID: 2026-04-28-34
DIME Test ID: 2026-04-28-34-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-05-11
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 05/04/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2190.8 g
Mass Loss: 189.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.27 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 7.5%
Test was verified on 5/11/2026 ✔