Summary for Test 2026-04-08-71-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001153
DEA: 081L3104
EFIS: 0820000020
DIST-CO-RTE-PM08-RIV-74-11.8/17.3
Award Date06/06/2025
Closeout DateNot set
Work DescriptionRHMA (GAP GRADED), REPLACE AC SURF, AND COLD PLANE AC PVMT.
Location DescriptionRIVERSIDE COUNTY IN LAKE ELSINORE FROM GRAND AVENUE TO ROUTE 15/74 SEPARATION
QA Service Level1 (Verified on 05/05/2025)

Sample Information

Sample Taken Date04/08/2026 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/13/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameR J Noble Company-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2026-04-08-71
DIME Test ID: 2026-04-08-71-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-05-12

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 05/07/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.258 grams
Mass of container #2 before test (m2i): 207.187 grams
Mass of container #1 after test (m1f): 203.211 grams
Mass of container #2 after test (m2f): 207.139 grams
Mass of empty container #1: 168.201 grams
Mass of empty container #2: 171.915 grams
Mass correction factor: 0.006
Average mass change: -0.129 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/12/2026