Summary for Test 2018-03-12-1-29
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 210828 DEA: 07290704 EFIS: 0712000076 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-0.9/2.0 |
| Award Date | 04/06/2016 |
| Closeout Date | 06/25/2019 |
| Work Description | RESTORE BRIDGE SEISMIC. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 06/03/2016) |
Sample Information
| Sample Taken Date | 03/12/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2018 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Fastener Assembly |
| The quantity of what the sample constitutes | 425 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
| Title of sampler | QA | Telephone number of sampler | 7072903887 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | C and K Johnson | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S38-041-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 100C650BA30G, 100C500BA30G, 100C850BA30G |
|---|---|---|---|
| Heat Number(s) | 10449580, DL17104510, 10497570, DL17105145, 174328 | Nut Mfg. Lot Number(s) | 399038C |
| Washer Mfg. Lot Number(s) | 306322 | Bolt Specification | A325 |
| Bolt Length(s) | 5", 6.5", 8.5" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | Galvanized |
| Diameter/Size | 1 inch | Bolt Mfg. Lot Number | 773399, 402895A, 791030 |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-03-12-1
DIME Test ID: 2018-03-12-1-29
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-03-27
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 03/20/2018
Sample No.: 1A
Rocap Number: 100C650BA30G
Heat Number(s): no data
Mfg. Lot Number: 399038C
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH N
Size: 1 in
Bolt Length: no data
Measurement Average: 3.29 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/20/2018 ✔