Summary for Test 2026-03-05-68-3
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1002039 DEA: 043X9804 EFIS: 0425000353 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/05/2026 | Sample Unique Key | 68 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/06/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/8 Con Agg |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Valdez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex Pleasanton | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0009 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-03-05-68
DIME Test ID: 2026-03-05-68-3
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2026-05-07
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Christian Sousa
Date of test: 03/06/2026
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 48
Sand reading (test 1): 35
Clay reading (test 2): 50
Sand reading (test 2): 35
Clay reading (test 3): 50
Sand reading (test 3): 37
Sand equivalent (test 1): 73
Sand equivalent (test 2): 70
Sand equivalent (test 3): 74
Sand equivalent before temperature correction: 73
Sand equivalent after temperature correction: 73
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2026 ✔