Summary for Test 2026-04-29-59-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000759
DEA: 074X9704
EFIS: 0716000335
DIST-CO-RTE-PM07-LA,-1-42.4
Award Date01/15/2025
Closeout DateNot set
Work DescriptionCONSTRUCT DRILLED HOLE AND DRILLED HOLE (ROCK SOCKET).
Location DescriptionLOS ANGELES COUNTY IN MALIBU AT 0.1 MILE SOUTH OF BIG ROCK DRIVE
QA Service Level1 (Verified on 11/25/2024)

Sample Information

Sample Taken Date04/29/2026 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing05/01/2026 Sample typeAcceptance
A brief description of the sample4X8 PCC cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byRachel
Last name of sampler or witnessed byCuneo Title of samplerAssistant Structure Representative
Telephone number of sampler Laboratory sample identification26-122
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociate Ready Mix
Transportation Laboratory (TL) Number042926 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSL4KCNIMK
The truck number from where the sample was collected2 The batch plant ticket number from where the sample was collected7791346
Concrete batch plantAssociated Ready Mix Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-04-29-59
DIME Test ID: 2026-04-29-59-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-05-06

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 05/06/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 79644 lb
Maximum load on cylinder 2: 71613 lb
Maximum load on cylinder 3: 73440 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 6305.9 psi
Compressive strength of cylinder 2: 5670.1 psi
Compressive strength of cylinder 3: 5814.7 psi
Compressive strength (to nearest 10 psi): 5930 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/6/2026 ✔