Summary for Test 2026-04-20-39-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000903
DEA: 081M0404
EFIS: 0821000091
DIST-CO-RTE-PM08-SBD-40-R140.0/R142.2
Award Date06/06/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC & RHMA, VEGETATION CONTROL (MINOR CONC), MGS, AND HTCB.
Location DescriptionSAN BERNARDINO COUNTY IN NEEDLES FROM FOX WASH OVERFLOW TO L STREET UNDERCROSSING
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date04/20/2026 Sample Unique Key39
Date that the sample was received by the laboratory/organization performing the testing04/22/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byFrancisco
Last name of sampler or witnessed byRUVALCABA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite-Desert -INDIO
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-04-20-39
DIME Test ID: 2026-04-20-39-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-05-06

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: David Valenzuela
Date of test: 05/06/2026
Time of test: 8:12 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 77.9 %
Viscosity reading #1 (A) : 0.389 Pa-s
Viscosity reading #2 (B) : 0.391 Pa-s
Viscosity reading #3 (C): 0.388 Pa-s
Average viscosity: 0.389 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/6/2026 ✔