Summary for Test 2026-04-20-36-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 995493
DEA: 081G6704
EFIS: 0816000049
DIST-CO-RTE-PM08-RIV-79-5.4/11.4
Award Date05/23/2024
Closeout DateNot set
Work DescriptionHOT MIX ASPHALT, SOIL NAIL, STRUCTURAL CONCRETE AND ROADWAY EXC.
Location DescriptionRIVERSIDE COUNTY NEAR TEMECULA FROM 0.4 MILE SOUTH OF SAGE ROAD TO 1.1 MILES SOUTH OF PAUBA ROAD
QA Service Level1 (Verified on 12/18/2023)

Sample Information

Sample Taken Date04/20/2026 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/23/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byJACOB-RJ BOBLE QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameR J Noble Company-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-04-20-36
DIME Test ID: 2026-04-20-36-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-05-04

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 05/04/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.166 grams
Mass of container #2 before test (m2i): 206.913 grams
Mass of container #1 after test (m1f): 203.162 grams
Mass of container #2 after test (m2f): 206.911 grams
Mass of empty container #1: 168.201 grams
Mass of empty container #2: 171.915 grams
Mass correction factor: 0.006
Average mass change: -0.003 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/4/2026