Summary for Test 2026-04-24-59-1
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001245 DEA: 040AA624 EFIS: 0419000518 |
|---|---|
| DIST-CO-RTE-PM | 04-SF-1-0.9/5.8 |
| Award Date | 07/23/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, HMA (TYPE A) AND INDIVIDUAL SLAB REPLACEMENT. |
| Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM HOLLOWAY AVENUE TO CALIFORNIA STREET |
| QA Service Level | 1 (Verified on 10/23/2025) |
Sample Information
| Sample Taken Date | 04/24/2026 | Sample Unique Key | 59 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 1/2 HMA + 15% RAP |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Lohman |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Peninsula Road Materials-RC | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 99-35-0012 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Peninsula Road Materials | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-04-24-59
DIME Test ID: 2026-04-24-59-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-05-04
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 04/25/2026
Clay Level (Test 1): 5
Sand Level (Test 1): 4.3
Clay Level (Test 2): 4.9
Sand Level (Test 2): 4
Clay Level (Test 3): 4.8
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 86
Sand Equivalent (Test 2): 82
Sand Equivalent (Test 3): 84
Sand Equivalent: 84
General comments (publicly viewable) (Max 1000 characters): PSUE Sample
3 SE's and its average.
Test was verified on 5/4/2026 ✔