Summary for Test 2026-04-30-36-1
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001360 DEA: 09374804 EFIS: 0918000020 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-115.0 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BUILDING WORK AND PLACE HMA (TYPE A). |
| Location Description | INYO COUNTY IN BISHOP AT THE DISTRICT OFFICE AT 500 SOUTH MAIN STREET |
| QA Service Level | 1 (Verified on 07/09/2025) |
Sample Information
| Sample Taken Date | 04/30/2026 | Sample Unique Key | 36 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/30/2026 | Sample type | Acceptance |
| A brief description of the sample | 1"x#4 Con Agg & Con Sand | The quantity of what the sample constitutes | 2000cy |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Young | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | CA-01 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | 7/11 Bishop | |
| Transportation Laboratory (TL) Number | 5305 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | Lab Footings | |
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile at Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-04-30-36
DIME Test ID: 2026-04-30-36-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-05-01
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 04/30/2026
Clay Level (Test 1): 5.4
Sand Level (Test 1): 3.8
Clay Level (Test 2): 5.2
Sand Level (Test 2): 3.6
Clay Level (Test 3): 5.3
Sand Level (Test 3): 3.6
Sand Equivalent (Test 1): 71
Sand Equivalent (Test 2): 70
Sand Equivalent (Test 3): 68
Sand Equivalent: 70
General comments (publicly viewable) (Max 1000 characters): Con Sand
Test was verified on 5/1/2026 ✔