Summary for Test 2026-04-27-15-5

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1000970
DEA: 031J6304
EFIS: 0321000023
DIST-CO-RTE-PM03-SAC-99-6.04/7.06
Award DateNot set
Closeout DateNot set
Work DescriptionWILLOW SLOUGH REPLACEMENT
Location DescriptionSACRAMENTO COUNTY NEAR ELK GROVE FROM 0.2 MILE NORTH OF ARNO ROAD TO 0.4 MILE SOUTH OF DILLARD ROAD
QA Service Level1 (Verified on 02/13/2025)

Sample Information

Sample Taken Date04/27/2026 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/27/2026
Sample typeQuality Control A brief description of the sample1 cubic foot
The quantity of what the sample constitutes1 cubic foot From where was the sample collectedFabricator
First name of sampler or witnessed byPatrick Last name of sampler or witnessed byWright
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameConFab Lathrop Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberL_85M1L
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected14147
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 1B, 3rd Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-04-27-15
DIME Test ID: 2026-04-27-15-5
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-04-28

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jerry Xiong
Date of test: 04/27/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1: 8.27 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 66038 lb
Maximum load on cylinder 2: 75879 lb
Maximum load on cylinder 3: 73132 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 1 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 5700 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/28/2026