Summary for Test 2026-04-13-4-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 1001469
DEA: 120K62U4
EFIS: 1224000090
DIST-CO-RTE-PM12-ORA, -5-R25.8/30.3
Award Date11/12/2025
Closeout DateNot set
Work DescriptionCONST BRIDGE, RW, SW, PAVEMENT, DRAINAGE, AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE AND TUSTIN FROM YALE AVENUE OVERCROSSING TO ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 08/13/2025)

Sample Information

Sample Taken Date04/13/2026 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/22/2026
Sample typeQuality Assurance A brief description of the sample#7 rebar Gr60 A706 6'-6" hoops
The quantity of what the sample constitutes218 pcs From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of samplerQuality Assurance Inspector Telephone number of sampler9095268064
Laboratory sample identification Linked DIME Sample ID2026-04-13-4
The fabricator/manufacturer/facility nameMartines Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL161-025-26 Structure unique identifier
Structure nameBridge Bid Item3944278

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)381924
Hoop Manufacturer Lot Number(s)Lots 1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop6'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyMartinez Steel Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2026-04-13-4
DIME Test ID: 2026-04-13-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-04-28

Test Results


Number of Samples: 8
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/28/2026
UTM: NA
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11170.605563092500Okay NeckingKleinfelder
22170.605449091000Okay NeckingKleinfelder
33170.605591093000Okay NeckingKleinfelder
44170.605420090500Affected ZoneKleinfelder
51270.605569093000Okay NeckingKleinfelder
62270.605556092500Okay NeckingKleinfelder
73270.605462091000Okay NeckingKleinfelder
84270.605427090500Okay NeckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/28/2026