Summary for Test 2026-04-21-50-4
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1002115 DEA: 09433704 EFIS: 0926000058 |
|---|---|
| DIST-CO-RTE-PM | 09---unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/21/2026 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA-A-SP PG70-10 R25 |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
| Title of sampler | QC | Telephone number of sampler | |
| Laboratory sample identification | PSU-01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Solari Plant | Transportation Laboratory (TL) Number | 5292 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-04-21-50
DIME Test ID: 2026-04-21-50-4
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-04-28
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 04/24/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4256.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6297.0 g
Mass of HMA Sample prior to ignition: 2041.0 g
Mass Loss: 100.7 g
Mass of aggregate remaining after ignition: 1940.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.57 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.36 %
General comments (publicly viewable) (Max 1000 characters): PSU-01
Test was verified on 4/28/2026 ✔