Summary for Test 2026-04-22-34-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1001573 DEA: 060X2904 EFIS: 0618000050 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-33-13.9/16.7 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, CL 2 AB, CURB RAMPS AND MOBILIZATION. |
| Location Description | FRESNO COUNTY IN AND NEAR COALINGA FROM ENTERPRISE PARKWAY TO LOS GATOS CREEK SOUTH CHANNEL BRIDGE |
| QA Service Level | 1 (Verified on 09/15/2025) |
Sample Information
| Sample Taken Date | 04/22/2026 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/23/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Placed During Shift |
| The quantity of what the sample constitutes | 9 4x8 Compression Strength Cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Noah | Last name of sampler or witnessed by | Hunt |
| Title of sampler | Senior Materials Tester | Telephone number of sampler | |
| Laboratory sample identification | 5 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | JJJ Redi-Mix Coalinga | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 631000 |
|---|---|---|---|
| The truck number from where the sample was collected | J81 | The batch plant ticket number from where the sample was collected | 42691 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Location C-42 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2026-04-22-34
DIME Test ID: 2026-04-22-34-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-04-27
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 04/27/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 3.99 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 39263 lb
Maximum load on cylinder 2: 37947 lb
Maximum load on cylinder 3: 38610 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 6
Type of fracture pattern of cylinder 3: 6
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 5 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.5 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3141.0 psi
Compressive strength of cylinder 2: 3018.9 psi
Compressive strength of cylinder 3: 3071.6 psi
Compressive strength (to nearest 10 psi): 3080 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/27/2026 ✔
