Summary for Test 2026-03-19-13-13

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/19/2026 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/26/2026
Sample typeQuality Assurance A brief description of the sampleF1554 Hex Bolt
The quantity of what the sample constitutes786 From where was the sample collectedFabricator
First name of sampler or witnessed byJamie Last name of sampler or witnessed byDoe
Title of samplerQuality Assurance Inspector Telephone number of sampler916-838-4505
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS50-023-26 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)na
Heat Number(s)256375 Nut Mfg. Lot Number(s)na
Washer Mfg. Lot Number(s)na Bolt SpecificationASTM F1554 gr 105
Bolt Length(s)15" Nut Specificationna
Washer Specificationna FinishHDG
Diameter/Size1-1/4" Bolt Mfg. Lot Number60653
Rocap Test Requirement(s)na Lubricant Requirements(s)na
Washer Inner Diameter(s)888

Test Details

DIME Sample ID: 2026-03-19-13
DIME Test ID: 2026-03-19-13-13
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-04-28

Test Results


Number of Bolt Samples: 6
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/24/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A2563751.2514525000Yield 124,000Atlas
21B2563751.2514531000Yield 130,000Atlas
31C2563751.2514481000Yield 128,000Atlas
41D2563751.2514433000YieAtlas
51E2563751.2514368000Atlas
61F2563751.2512724000Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/28/2026