Summary for Test 2026-04-16-48-2

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 1000611
DEA: 120R32U4
EFIS: 1222000054
DIST-CO-RTE-PM12-ORA-55-0.2/R17.8
Award Date02/07/2025
Closeout DateNot set
Work DescriptionCOLD PLANE, PLACE RHMA, REPLACE CB, SIGNS AND MODIFY LIGHTING SYSTEM.
Location DescriptionORANGE COUNTY FROM 0.1 MILE SOUTH OF ROUTE 55/1 SEPARATION IN NEWPORT BEACH TO ROUTE 55/91 SEPARATION IN ANAHEIM
QA Service Level1 (Verified on 09/30/2024)

Sample Information

Sample Taken Date04/16/2026 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/17/2026
Sample typeQuality Assurance A brief description of the sampleRSC Flexural Beams
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byMB Pro Last name of sampler or witnessed byMB PRO
Title of sampler Telephone number of sampler
Laboratory sample identification26-0068 Linked DIME Sample ID
The fabricator/manufacturer/facility nameShort Load Concrete Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-EHI
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedUnknown
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampledInside lanes 55 fwy in both NB / SB around Lincoln
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-04-16-48
DIME Test ID: 2026-04-16-48-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2026-04-23

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Dan Morris
Date of test: 04/23/2026
Identification number: 26-0068-4-6
Width of specimen: 5.9375 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 5.9375 inch
Depth of specimen: 6.0625 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7320 lb
Maximum load applied 2: 7180 lb
Maximum load applied 3: 6820 lb
Curing history and apparent moisture condition of the specimen: Sand pit/Lime water bath (Contract Specs.)
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 630 psi
Modulus of rupture 2: 600 psi
Modulus of rupture 3: 590 psi
Modulus of rupture average: 610 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
26-0068B7Dpdf215.50 KB04/23/20262026-04-16-48-2   Info

Test was verified on 4/23/2026