Summary for Test 2026-03-17-10-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/17/2026 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | All Thread Anchor Bolts |
| The quantity of what the sample constitutes | 500 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jamie | Last name of sampler or witnessed by | Doe |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 916-838-4505 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales, Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-022-26 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | na |
|---|---|---|---|
| Heat Number(s) | 1000229370 | Nut Mfg. Lot Number(s) | na |
| Washer Mfg. Lot Number(s) | na | Bolt Specification | ASTM F1554 gr 105 |
| Bolt Length(s) | 10" | Nut Specification | na |
| Washer Specification | na | Finish | HDG |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | heat # 1000229370 |
| Rocap Test Requirement(s) | na | Lubricant Requirements(s) | na |
| Washer Inner Diameter(s) | 888 |
Test Details
DIME Sample ID: 2026-03-17-10
DIME Test ID: 2026-03-17-10-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-04-28
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/21/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 1000229370 | 0.875 | 61400 | 0 | 0 | NA | Atlas |
| 2 | 1B | 1000229370 | 0.875 | 61150 | 0 | 0 | NA | Atlas |
| 3 | 1C | 1000229370 | 0.875 | 61490 | 0 | 0 | NA | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/28/2026 ✔