Summary for Test 2026-03-23-65-2
Test performed: ASTM D217-21Project Information
| Project Identifiers | Project ID: 1000851 DEA: 07351704 EFIS: 0718000204 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-118,118-15.6/R17.9 |
| Award Date | 03/25/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RUBBERIZED HMA. |
| Location Description | VENTURA COUNTY IN MOORPARK AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 03/11/2025) |
Sample Information
| Sample Taken Date | 03/23/2026 | Sample Unique Key | 65 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2026 |
| Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | Pham |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan-Sun Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2026-03-23-65
DIME Test ID: 2026-03-23-65-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2026-04-17
Test Results
Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 04/15/2026
Unworked Penetration, Test 1: 37 0.1 mm
Unworked Penetration, Test 2: 38 0.1 mm
Unworked Penetration, Test 3: 37 0.1 mm
Unworked Penetration: 37 0.1 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2026 ✔