Summary for Test 2026-04-07-1-1

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 214151
DEA: 080R0104
EFIS: 0812000007
DIST-CO-RTE-PM08-RIV-91-R0.3
Award Date08/27/2025
Closeout DateNot set
Work DescriptionSTR EXC, FURNISH PRECAST RCB CULVERT AND STR CONC RETAINING WALL.
Location DescriptionRIVERSIDE COUNTY NEAR CORONA AT 0.7 MILES WEST OF GREEN RIVER ROAD OVERCROSSING
QA Service Level1 (Verified on 05/09/2019)

Sample Information

Sample Taken Date04/07/2026 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/10/2026
Sample typeQuality Assurance A brief description of the sample#9 rebar with head
The quantity of what the sample constitutes16 pcs From where was the sample collectedFabricator
First name of sampler or witnessed byJoaquin Last name of sampler or witnessed byMoreno
Title of samplerQuality Assurance Inspector Telephone number of sampler9095268064
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartinez Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL161-022-26 Structure unique identifier
Structure nameRIVERSIDE COUNTY NEAR CORONA AT 0.7 MILES WEST OF GREEN RIVER ROAD OVERCROSSING Bid Item3935278

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)046126 Head Manufacturer Lot Number(s)Eaton 5393914
Rebar Size#9 Headed Bar Model NameLU28DR16D
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeCircular Rebar ManufacturerCascade Steel
Head ManufacturerErico Lenton nVent Head FabricatorErico Lenton nVent
Material Standard CodeASTM A706 Headed Bar Unique ID4FW-18-01

Test Details

DIME Sample ID: 2026-04-07-1
DIME Test ID: 2026-04-07-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-04-15

Test Results


Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/15/2026
UTM: NA
Temperature: 0 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1119865098500NAKleinfelder
211100240100000NAKleinfelder
3119927099500NAKleinfelder
4119881099000NAKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/15/2026