Summary for Test 2026-04-14-9-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 995236
DEA: 060U2904
EFIS: 0616000001
DIST-CO-RTE-PM06-KER-184-1.1/8.3
Award Date08/14/2025
Closeout DateNot set
Work DescriptionCOLD PLANE & OVERLAY WITH HMA/RHMA, CONSTRUCT SIDEWALKS & CURB RAMPS.
Location DescriptionKERN COUNTY NEAR BAKERSFIELD FROM WHARTON AVENUE TO EDISON HIGHWAY
QA Service Level1 (Verified on 12/18/2024)

Sample Information

Sample Taken Date04/14/2026 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/15/2026
Sample typeAcceptance A brief description of the sample1/2" HMA- A with 15% Rap
The quantity of what the sample constitutes750 tons L2SL3 From where was the sample collectedSource
First name of sampler or witnessed byAlex Last name of sampler or witnessed byEscobar
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid Item3936550

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number2
Sublot number3 HMA Mix Number
Binder content (%)4.9 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder Supplier
RAP content (%)Not set WMA AdditivesNo
Antistrip type.8% Lime

Test Details

DIME Sample ID: 2026-04-14-9
DIME Test ID: 2026-04-14-9-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-04-15

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Alex Escobar
Date of test: 04/15/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3977.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 5510.1 g
Mass of HMA Sample prior to ignition: 1533.1 g
Mass Loss: 81.6 g
Mass of aggregate remaining after ignition: 1451.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.74 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.58 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0U2904_37043_260414_T308_L2SL3pdf154.28 KB04/15/20262026-04-14-9-2   Info

Test was verified on 4/15/2026