Summary for Test 2026-03-11-65-4

Test performed: AASHTO T313-2025

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/11/2026 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/02/2026
Sample typeVerification A brief description of the sampleTank 6
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byKeven Last name of sampler or witnessed byHeitschmidt
Title of sampler Telephone number of sampler
Laboratory sample identificationPG7622M31126T6 Linked DIME Sample ID2026-03-11-60
The fabricator/manufacturer/facility nameChowchilla CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 76-22 M
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Chowchilla - Chowchilla CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2026-03-11-65
DIME Test ID: 2026-03-11-65-4
Testing Lab: Atlas - Denver
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2026-04-13

Test Results


Input Type: Calculated
Tester's full name: Erik Svensson
Date of test: 04/13/2026
Paired test specimens performed?: no data
BBR Software for individual test specimens: no data
Maximum test bath temperature at 240 S: 0.0 C
Minimum test bath temperature at 240 S: 0.0 C
Time of test load application: no data
File name of test data: no data
Time test specimen in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficients and least square fit R² value: 0.000
Comments: no data
Regression coefficient a: 0.000
Regression coefficient b: 0.000
Regression coefficient c: 0.000
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Loading time 8.0 s: 0.0 s
Load at 8.0 s: 0.0 mN
Test specimen deflection 8.0 s: 0.000 µm
Measured Stiffness Modulus 8.0 s: 0.000 MPa
Estimated Stiffness Modulus 8.0 s: 0.000 MPa
Difference between stiffness moduli 8.0 s: 0.00 %
Estimated m-value 8.0 s: 0.000
Loading time 15.0 s: 0.0 s
Load at 15.0 s: 0.0 mN
Test specimen deflection 15.0 s: 0.000 µm
Measured Stiffness Modulus 15.0 s: 0.000 MPa
Estimated Stiffness Modulus 15.0 s: 0.000 MPa
Difference between stiffness moduli 15.0 s: 0.00 %
Estimated m-value 15.0 s: 0.000
Loading time 30.0 s: 0.0 s
Load at 30.0 s: 0.0 mN
Test specimen deflection 30.0 s: 0.000 µm
Measured Stiffness Modulus 30.0 s: 0.000 MPa
Estimated Stiffness Modulus 30.0 s: 0.000 MPa
Difference between stiffness moduli 30.0 s: 0.00 %
Estimated m-value 30.0 s: 0.000
Loading time 60.0 s: 0.0 s
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Test specimen deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 0.000 MPa
Estimated Stiffness Modulus 60.0 s: 80.000 MPa
Difference between stiffness moduli 60.0 s: 0.00 %
Estimated m-value 60.0 s: 0.332
Loading time 120.0 s: 0.0 s
Load at 120.0 s: 0.0 mN
Test specimen deflection 120.0 s: 0.000 µm
Measured Stiffness Modulus 120.0 s: 0.000 MPa
Estimated Stiffness Modulus 120.0 s: 0.000 MPa
Difference between stiffness moduli 120.0 s: 0.00 %
Estimated m-value 120.0 s: 0.000
Loading time 240.0 s: 0.0 s
Load at 240.0 s: 0.0 mN
Test specimen deflection 240.0 s: 0.000 µm
Measured Stiffness Modulus 240.0 s: 0.000 MPa
Estimated Stiffness Modulus 240.0 s: 0.000 MPa
Difference between stiffness moduli 240.0 s: 0.00 %
Estimated m-value 240.0 s: 0.000
General comments (publicly viewable) (Max 1000 characters): BBR

Test was verified on 4/13/2026