Summary for Test 2026-03-13-24-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000640
DEA: 074P8504
EFIS: 0719000259
DIST-CO-RTE-PM07-VEN-1-1.0/1.3
Award Date11/20/2024
Closeout DateNot set
Work DescriptionINSTALL MARKED CROSSWALK WITH PEDESTRIAN HYBRID BEACON SIGNALS.
Location DescriptionVENTURA COUNTY FROM 0.1 MILE SOUTH OF YERBA BUENA ROAD TO 0.1 MILE NORTH OF LITTLE SYCAMORE CREEK BRIDGE
QA Service Level1 (Verified on 09/24/2024)

Sample Information

Sample Taken Date03/13/2026 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/14/2026
Sample typeAcceptance A brief description of the sample4x8 concrete cylinders (3 total)
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byArmando Last name of sampler or witnessed bySerratos
Title of sampler Telephone number of sampler
Laboratory sample identification26-048 Linked DIME Sample ID
The fabricator/manufacturer/facility nameState Ready Mix Transportation Laboratory (TL) Number3112026
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number590SN2010
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected90166
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-03-13-24
DIME Test ID: 2026-03-13-24-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-04-10

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 04/10/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 47510 lb
Maximum load on cylinder 2: 52217 lb
Maximum load on cylinder 3: 56180 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 3779.6 psi
Compressive strength of cylinder 2: 4114.8 psi
Compressive strength of cylinder 3: 4427.1 psi
Compressive strength (to nearest 10 psi): 4110 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/10/2026