Summary for Test 2025-09-25-137-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000256
DEA: 120S2804
EFIS: 1220000014
DIST-CO-RTE-PM12-ORA-5-9.6/10.4
Award Date06/24/2024
Closeout Date09/01/2026
Work DescriptionADD SECONDARY AUXILIARY LANE.
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO FROM ROUTE 74/5 SEPARATION TO 0.5 MILE SOUTH OF JUNIPERO SERRA ROAD UNDERCROSSING
QA Service Level1 (Verified on 05/14/2024)

Sample Information

Sample Taken Date09/25/2025 Sample Unique Key137
Date that the sample was received by the laboratory/organization performing the testing09/26/2025 Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes1 per batch
From where was the sample collectedJob Site First name of sampler or witnessed byAdrian
Last name of sampler or witnessed byMireles Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex - Irvine
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1614705
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31756636
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCIDH @ Location 1 (First Lift). Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-09-25-137
DIME Test ID: 2025-09-25-137-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-04-10

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jorge Reyes
Date of test: 11/06/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 155750 lb
Maximum load on cylinder 2: 162090 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5620 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/10/2026 ✔