Summary for Test 2018-02-21-6-1

Test performed: ASTM C109-11

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/21/2018 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing02/21/2018 Sample typeControl Sample
A brief description of the sampleControl for Fly Ash The quantity of what the sample constitutes6 cubes
From where was the sample collectedOther First name of sampler or witnessed byTimothy
Last name of sampler or witnessed byOMalley Title of samplerTET
Telephone number of samplerUnknown Laboratory sample identificationCM189002
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNevada Cement
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandNevada
MillFernley Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2018-02-21-6
DIME Test ID: 2018-02-21-6-1
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2019-03-22

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Calculated
Tester's full name: Timothy OMalley
Date of test: 02/28/2018
Age of specimen: 7 days
The amount of flow (In percent): 118 %
The amount of water used (In percent): 48.4 %
Maximum load of 1st specimen (lb): 14641 lb
Maximum load of 2nd specimen (lb): 16089 lb
Maximum load of 3rd specimen (lb): 14612 lb
Compressive strength of 1st specimen (psi): 3660 psi
Compressive strength of 2nd specimen (psi): 4022 psi
Compressive strength of 3rd specimen (psi): 3653 psi
Average Compressive strength (to nearest 10 psi): 3778 psi
General comments (publicly viewable) (Max 1000 characters): 7 day break -- Specimen 2 break was outside allowable range. Correct final result is 3660 PSI.

Test was verified on 3/22/2019