Summary for Test 2026-02-04-80-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1002080 DEA: 081T4604 EFIS: 0826000072 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-330-34/42 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/08/2026) |
Sample Information
| Sample Taken Date | 02/04/2026 | Sample Unique Key | 80 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/04/2026 | Sample type | Acceptance |
| A brief description of the sample | Native Subgrade | The quantity of what the sample constitutes | 26.4 kg |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Gabriel |
| Last name of sampler or witnessed by | Ramirez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | SR-330 Downbound, Slope Area of Drainage Pipe @ PM 34.70 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-02-04-80
DIME Test ID: 2026-02-04-80-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-04-09
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 02/04/2026
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 3
Depth: 8"
Material No.: no data
Material Type: Native Subgrade
Impact By: Gabriel Ramirez
Standard Count Density: 1730 g/cc
Count or Density 1: 927 g/cc
Count or Density 2: 942 g/cc
Count or Density 3: 1019 g/cc
Standard Count Moisture: 630 g/cc
Moisture Count 1: 178 g/cc
Moisture Count 2: 82 g/cc
Moisture Count 3: 93 g/cc
Sum of Count or Density: 2888 g/cc
Average of Count or Density: 963 g/cc
Sum of Moisture Count: 353 g/cc
Average of Moisture Count: 118 g/cc
Count Ratio Density: 0.56
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 94.2 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2026 ✔
