Summary for Test 2026-02-23-30-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000103 DEA: 081J8604 EFIS: 0818000123 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10,15,40,58,60,etc.-Var |
| Award Date | 05/01/2024 |
| Closeout Date | Not set |
| Work Description | MODIFYING CMS SYSTEMS AND FURNISH SIGN STRUCTURE (VERSATILE TRUSS). |
| Location Description | SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/15/2024) |
Sample Information
| Sample Taken Date | 02/23/2026 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/23/2026 | Sample type | Acceptance |
| A brief description of the sample | Class II Aggregate Base | The quantity of what the sample constitutes | 25.9 kg |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Maqsud |
| Last name of sampler or witnessed by | Ahmed | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | SR-210 EB, MVP @ PM R0.81, Sta 66+75 - 67+55 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-02-23-30
DIME Test ID: 2026-02-23-30-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-04-09
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Maqsud Ahmed
Date of test: 02/23/2026
Gage No.: 30692
Test No.: 1
Nuclear By: Maqsud Ahmed
Non-Bias Plan No.: 4
Depth: 5"
Material No.: no data
Material Type: Class II Aggregate Base
Impact By: Maqsud Ahmed
Standard Count Density: 1634 g/cc
Count or Density 1: 1519 g/cc
Count or Density 2: 1613 g/cc
Count or Density 3: 1511 g/cc
Standard Count Moisture: 643 g/cc
Moisture Count 1: 58 g/cc
Moisture Count 2: 64 g/cc
Moisture Count 3: 71 g/cc
Sum of Count or Density: 4643 g/cc
Average of Count or Density: 1548 g/cc
Sum of Moisture Count: 193 g/cc
Average of Moisture Count: 64 g/cc
Count Ratio Density: 0.95
Count Ratio Moisture: 0.1
Calculated Percent Relative Compaction: 92.6 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2026 ✔