Summary for Test 2026-03-18-56-4

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000997
DEA: 010J2104
EFIS: 0118000190
DIST-CO-RTE-PM01-DN-101-R2.6/23.9
Award Date06/06/2025
Closeout DateNot set
Work DescriptionRHMA, HMA, AND COLD PLANE ASPHALT CONCRETE PAVEMENT.
Location DescriptionDEL NORTE COUNTY IN AND NEAR KLAMATH FROM 1.2 MILES SOUTH OF KLAMATH RIVER OVERFLOW TO 1.1 MILE NORTH OF HAMILTON ROAD
QA Service Level1 (Verified on 03/21/2025)

Sample Information

Sample Taken Date03/18/2026 Sample Unique Key56
Date that the sample was received by the laboratory/organization performing the testing03/27/2026 Sample typeQuality Assurance
A brief description of the samplepg 58-22 The quantity of what the sample constitutes1 can of binder
From where was the sample collectedSource First name of sampler or witnessed byLEE
Last name of sampler or witnessed byR Title of samplerTET
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMERCER FRASER
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form00000
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierWestern Emulsions - White City Emulsion Plant - White City OR MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-03-18-56
DIME Test ID: 2026-03-18-56-4
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-04-09

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 04/09/2026
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 12.8 %
Viscosity reading #1 (A) : 321 cP
Viscosity reading #2 (B) : 321 cP
Viscosity reading #3 (C): 321 cP
Average viscosity : 0.321 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOCITY AT 135C

Test was verified on 4/9/2026 ✔