Summary for Test 2026-04-08-19-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1001575 DEA: 061H9604 EFIS: 0625000104 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-46,119-VAR |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PAVEMENT AND PLACING RHMA TYPE G. |
| Location Description | KERN COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/15/2025) |
Sample Information
| Sample Taken Date | 04/08/2026 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2026 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA A |
| The quantity of what the sample constitutes | L1SL2- 36 boxes HMA, 4bags of cold feed,, 2 bags of virgin aggrgate each bin and 2 bags of RAP | From where was the sample collected | Source |
| First name of sampler or witnessed by | Alex | Last name of sampler or witnessed by | Escobar |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Griffith Edmonston | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3933859 |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 2 | HMA Mix Number | |
| Binder content (%) | 7.5 | Virgin binder PG | PG 70-10 |
| Design binder PG | PG 70-10 | Binder Supplier | San Juaquin Refinery |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type | LIme 0.8% |
Test Details
DIME Sample ID: 2026-04-08-19
DIME Test ID: 2026-04-08-19-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-04-09
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Alex Escobar
Date of test: 04/09/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4322.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6479.7 g
Mass of HMA Sample prior to ignition: 2157.6 g
Mass Loss: 115.0 g
Mass of aggregate remaining after ignition: 2042.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.89 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-1H9604_37013_260408_T308_L1SL2 | 163.27 KB | 04/09/2026 | 2026-04-08-19-1 | Info |
Test was verified on 4/9/2026 ✔