Summary for Test 2026-04-06-20-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-27.5/34.3 |
| Award Date | 08/11/2025 |
| Closeout Date | Not set |
| Work Description | RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT. |
| Location Description | RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 09/02/2024) |
Sample Information
| Sample Taken Date | 04/06/2026 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2026 |
| Sample type | Acceptance | A brief description of the sample | Native Subgrade |
| The quantity of what the sample constitutes | 25.5 kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Gabriel | Last name of sampler or witnessed by | Ramirez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | SR-74 EB, Bus Pad @ Juniper Flats Rd, PM 27.5/34.33 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-04-06-20
DIME Test ID: 2026-04-06-20-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-04-08
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Gabriel Ramirez
Date of test: 04/06/2026
Gage No.: 36636
Test No.: 1
Nuclear By: Gabriel Ramirez
Non-Bias Plan No.: 7
Depth: 8"
Material No.: no data
Material Type: Native Subgrade
Impact By: Gabriel Ramirez
Standard Count Density: 1687 g/cc
Count or Density 1: 892 g/cc
Count or Density 2: 1139 g/cc
Count or Density 3: 1010 g/cc
Standard Count Moisture: 642 g/cc
Moisture Count 1: 118 g/cc
Moisture Count 2: 111 g/cc
Moisture Count 3: 103 g/cc
Sum of Count or Density: 3041 g/cc
Average of Count or Density: 1014 g/cc
Sum of Moisture Count: 332 g/cc
Average of Moisture Count: 111 g/cc
Count Ratio Density: 0.6
Count Ratio Moisture: 0.17
Calculated Percent Relative Compaction: 89.7 %
Reported Percent Relative Compaction: 90 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/8/2026 ✔