Summary for Test 2026-04-02-21-3
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1000762 DEA: 11430364 EFIS: 1118000109 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-79-20.2/53.0 |
| Award Date | 03/19/2025 |
| Closeout Date | Not set |
| Work Description | CULVERT REPAIR, GUARDRAIL, FLASHING BEACON AND SIGN REPLACEMENTS. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM WEST JUNCTION ROUTE 78 TO RIVERSIDE COUNTY LINE |
| QA Service Level | 1 (Verified on 05/02/2025) |
Sample Information
| Sample Taken Date | 04/02/2026 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2026 |
| Sample type | Quality Assurance | A brief description of the sample | Daily Production |
| The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Martin Marietta Lakeside | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23417105 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-04-02-21
DIME Test ID: 2026-04-02-21-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-04-08
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 04/07/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4024.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6065.2 g
Mass of HMA Sample prior to ignition: 2041.2 g
Mass Loss: 103.1 g
Mass of aggregate remaining after ignition: 1938.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.99 %
General comments (publicly viewable) (Max 1000 characters): Retest. Does not comply. Tested 4.99%, Max Accepted 4.95%
Test was verified on 4/8/2026 ✔