Summary for Test 2026-03-27-2-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001645 DEA: 051R1004 EFIS: 0523000125 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO, -1-32.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BRIDGE REPLACEMENT, HMA, AND RSP PROTECTION. |
| Location Description | SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 03/27/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #7 welded hoops |
| The quantity of what the sample constitutes | 1104 hoops | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Johnathan | Last name of sampler or witnessed by | Shoulders |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 046826 |
| Hoop Manufacturer Lot Number(s) | Lots 1-8 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 2'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade Steel |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-03-27-2
DIME Test ID: 2026-03-27-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-04-07
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 04/07/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 4 | 7 | 0.60 | 57910 | 96500 | ok necking | Kleinfelder |
| 2 | 2 | 4 | 7 | 0.60 | 57720 | 96000 | ok necking | Kleinfelder |
| 3 | 3 | 4 | 7 | 0.60 | 57900 | 96500 | ok necking | Kleinfelder |
| 4 | 4 | 4 | 7 | 0.60 | 59220 | 98500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/7/2026 ✔