Summary for Test 2026-03-18-29-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1000403
DEA: 120K91U4
EFIS: 1222000031
DIST-CO-RTE-PM12-ORA-91-R9.2/R11.4
Award Date01/03/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING
QA Service Level1 (Verified on 08/19/2024)

Sample Information

Sample Taken Date03/18/2026 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing03/20/2026
Sample typeQuality Assurance A brief description of the samplePT Strand
The quantity of what the sample constitutes18 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S337091-5, S337094-3 Number of Coils
Group Number Strand Diameter
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0517126, S0507026 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2026-03-18-29
DIME Test ID: 2026-03-18-29-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-04-06

Test Results


Number of Samples: 2
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 04/06/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0517126S337091-50.217608815806929.64.25AEC
2S0507026S337094-30.217611615762829.64.13AEC

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/6/2026