Summary for Test 2026-03-13-6-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1001248
DEA: 120K93U4
EFIS: 1224000084
DIST-CO-RTE-PM12-ORA-57,91-13.9/16.1,4.8/6.6
Award Date10/20/2025
Closeout DateNot set
Work DescriptionCONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS.
Location DescriptionANAHEIM AND PLACENTIA ON ROUTE 57 FROM WAGNER AVENUE OVERCROSSING TO 0.2 MILE NORTH OF MIRALOMA AVENUE OVERCROSSING AND ON ROUTE 91 FROM 0.1 MILE EAST OF ACACIA STREET UNDERCROSSING TO 0.2 MILE EAST OF LA PALMA AVENUE OVERCROSSING
QA Service Level1 (Verified on 06/16/2025)

Sample Information

Sample Taken Date03/13/2026 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/24/2026
Sample typeQuality Assurance A brief description of the sample1/2" Uncoated Seven Wire Steel Strand for Prestressed Concrete
The quantity of what the sample constitutes20 Strand Packs From where was the sample collectedFabricator
First name of sampler or witnessed byStephen Last name of sampler or witnessed byHaynes
Title of samplerQuality Assurance Inspector Telephone number of sampler5105931179
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePinnacle Prestress, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB408-008-26 Structure unique identifier
Structure name Bid Item3943675

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S133462-7, S133463-6, S133463-8, S133464-6, S133465-6, S133465-7, S133465-8, S133462-1, S133463-7, S133464-2, S133464-3, S133464-7, S133464-8, S133465-1, S133462-2, S133462-3, S133462-4, S133463-1, S133463-2, S133463-3 Number of Coils20
Group Number Strand Diameter.5 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0546825 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire Products Corporation

Test Details

DIME Sample ID: 2026-03-13-6
DIME Test ID: 2026-03-13-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-04-06

Test Results


Number of Samples: 20
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 04/06/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0546825S133464-80.153424864107129.34.86Kleinfelder
2S0546825S133462-20.153428994086628.35.11Kleinfelder
3S0546825S133464-60.153430924124029.13.87Kleinfelder
4S0546825S133463-70.153437214104229.43.71Kleinfelder
5S0546825S133465-70.153436384132029.13.96Kleinfelder
6S0546825S133465-60.153417874098828.94.11Kleinfelder
7S0546825S133463-80.153439914052428.64.21Kleinfelder
8S0546825S133464-20.153426124088529.33.56Kleinfelder
9S0546825S133462-70.153419193833329.23.85Kleinfelder
10S0546825S133465-10.153439594106628.64.48Kleinfelder
11S0546825S133463-30.153418114082028.74.48Kleinfelder
12S0546825S133463-20.153433034109828.73.92Kleinfelder
13S0546825S133465-80.153426774059728.34.7Kleinfelder
14S0546825S133463-10.153434604087328.94.19Kleinfelder
15S0546825S133462-40.153438584083028.84.25Kleinfelder
16S0546825S133463-60.153437794121930.03.74Kleinfelder
17S0546825S133462-10.153436934102629.24.67Kleinfelder
18S0546825S133462-30.153433824096628.84.93Kleinfelder
19S0546825S133464-30.153432964072928.73.77Kleinfelder
20S0546825S133464-70.153431674069628.93.95Kleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/6/2026