Summary for Test 2026-03-30-5-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1001307
DEA: 034J1204
EFIS: 0323000088
DIST-CO-RTE-PM03-YOL-16-37.3/37.8
Award Date09/05/2025
Closeout DateNot set
Work DescriptionHMA, FLASHING BEACON SYSTEM, AND ROADWAY EXCAVATION.
Location DescriptionYOLO COUNTY NEAR WOODLAND 0.2 MILE WEST OF COUNTY ROAD 95 TO 0.2 MILE EAST OF COUNTY ROAD 95
QA Service Level1 (Verified on 06/11/2025)

Sample Information

Sample Taken Date03/30/2026 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/30/2026
Sample typeQuality Assurance A brief description of the sampleProduction Startup Evaluation (3/4" 64-16 HMA SP RAP)
The quantity of what the sample constitutes750 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byEmilio Last name of sampler or witnessed byChavez
Title of samplerMaterials Tester Telephone number of sampler(530) 217-5934
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert (Woodland Hot Plant #306) Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormLot 1, Sublot 1 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number
Binder content (%)0.0 Virgin binder PG PG 64-16
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-03-30-5
DIME Test ID: 2026-03-30-5-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-04-03

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 04/02/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2135.2 g
Mass Loss: 131.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.93 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.21 %
General comments (publicly viewable) (Max 1000 characters): R1 OBC 4.7%

Test was verified on 4/3/2026