Summary for Test 2026-01-12-3-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001075 DEA: 040W0304 EFIS: 0420000164 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-580-0.02/6.3 |
| Award Date | 10/16/2025 |
| Closeout Date | Not set |
| Work Description | Replace existing tolling structure with open road tolling (ORT) system at the Richmond-San Rafael. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 03/13/2025) |
Sample Information
| Sample Taken Date | 01/12/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 5'-2" dia. hoops |
| The quantity of what the sample constitutes | 1 Lot of 129 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
| Title of sampler | Aso Steel Inspector | Telephone number of sampler | 9168266371 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Conco Companies Benicia | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-003-26 | Structure unique identifier | |
| Structure name | Toll Plaza Reconfiguration | Bid Item | 3933531 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4151011 |
| Hoop Manufacturer Lot Number(s) | H02 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 5'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel AZ |
| Welding Company | Conco Companies Benicia | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-01-12-3
DIME Test ID: 2026-01-12-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-04-02
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 04/02/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 40760 | 92500 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 40180 | 91500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 42150 | 96000 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 31170 | 71000 | affected zone | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/2/2026 ✔