Summary for Test 2026-03-09-29-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/09/2026 Sample Unique Key29
Date that the sample was received by the laboratory/organization performing the testing03/13/2026 Sample typePreliminary
A brief description of the sample64-16 The quantity of what the sample constitutes1 can of 64-16
From where was the sample collectedSource First name of sampler or witnessed byJAMES
Last name of sampler or witnessed byBREWSTER Title of samplerMREA
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Grantline
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-03-09-29
DIME Test ID: 2026-03-09-29-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-04-01

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 04/01/2026
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 16.0 %
Viscosity reading #1 (A) : 399 cP
Viscosity reading #2 (B) : 399 cP
Viscosity reading #3 (C): 399 cP
Average viscosity : 0.399 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOSITY AT 135C

Test was verified on 4/1/2026