Summary for Test 2026-02-05-62-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 1000481 DEA: 081C07U4 EFIS: 0824000168 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-27.5/34.3 |
| Award Date | 08/11/2025 |
| Closeout Date | Not set |
| Work Description | RUBBERIZED HMA, FIBER OPTIC CABLE SYSTEMS, AND COLD PLANE AC PAVEMENT. |
| Location Description | RIVERSIDE COUNTY AT AND NEAR ROMOLAND AND HOMELAND FROM BONNIE DRIVE TO WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 09/02/2024) |
Sample Information
| Sample Taken Date | 02/05/2026 | Sample Unique Key | 62 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2026 |
| Sample type | Acceptance | A brief description of the sample | Native Subgrade |
| The quantity of what the sample constitutes | 22.6 kg | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | MaryAnna | Last name of sampler or witnessed by | Landaverde |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Corner of SR-74 WB & Juniper Flats Rd NB, Intersection Curb | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2026-02-05-62
DIME Test ID: 2026-02-05-62-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-04-01
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: MaryAnna Landaverde
Date of test: 02/05/2026
Gage No.: 30691
Test No.: 1
Nuclear By: MaryAnna Landaverde
Non-Bias Plan No.: 7
Depth: 8"
Material No.: no data
Material Type: Native Subgrade
Impact By: MaryAnna Landaverde
Standard Count Density: 1598 g/cc
Count or Density 1: 872 g/cc
Count or Density 2: 793 g/cc
Count or Density 3: 704 g/cc
Standard Count Moisture: 657 g/cc
Moisture Count 1: 111 g/cc
Moisture Count 2: 73 g/cc
Moisture Count 3: 68 g/cc
Sum of Count or Density: 2369 g/cc
Average of Count or Density: 790 g/cc
Sum of Moisture Count: 252 g/cc
Average of Moisture Count: 84 g/cc
Count Ratio Density: 0.49
Count Ratio Moisture: 0.13
Calculated Percent Relative Compaction: 96.9 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/1/2026 ✔