Summary for Test 2025-11-08-32-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000567
DEA: 042K7404
EFIS: 0417000018
DIST-CO-RTE-PM04-MRN-37-R11.2/14.5
Award Date12/20/2024
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, PLACE RHMA AND REPLACE CONCRETE BARRIER.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM IGNACIO OVERHEAD TO PETALUMA RIVER BRIDGE
QA Service Level1 (Verified on 10/16/2024)

Sample Information

Sample Taken Date11/08/2025 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing11/08/2025 Sample typeQuality Assurance
A brief description of the sample1/2" RHMA-G WMA SP64-16 The quantity of what the sample constitutes150 tons
From where was the sample collectedJob Site First name of sampler or witnessed byKyle
Last name of sampler or witnessed byG Title of samplerPEI Tech
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Lake Herman
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Vulcan Lake Herman
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collected2 bags
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number16 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-11-08-32
DIME Test ID: 2025-11-08-32-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-04-06

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Jose Amparan Ruiz
Date of test: 11/17/2025
Cumulative Mass RetainedCumulative Percent Passing
4736.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
218.0 grams95 %
683.0 grams86 %
2605.0 grams45 %
484.2 grams
224.3 grams24 %
321.3 grams15 %
373.2 grams10 %
407.0 grams7 %
430.6 grams5 %
445.9 grams3.6 %
0.0 grams
General comments (publicly viewable) (Max 1000 characters): No. 4 limits: 26 - 38

Test was verified on 4/6/2026 ✔