Summary for Test 2025-10-24-69-5

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 1000567
DEA: 042K7404
EFIS: 0417000018
DIST-CO-RTE-PM04-MRN-37-R11.2/14.5
Award Date12/20/2024
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, PLACE RHMA AND REPLACE CONCRETE BARRIER.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM IGNACIO OVERHEAD TO PETALUMA RIVER BRIDGE
QA Service Level1 (Verified on 10/16/2024)

Sample Information

Sample Taken Date10/24/2025 Sample Unique Key69
Date that the sample was received by the laboratory/organization performing the testing10/29/2025 Sample typeQuality Assurance
A brief description of the sample3/4" HMA-SP The quantity of what the sample constitutes150 tons
From where was the sample collectedSource First name of sampler or witnessed byJose
Last name of sampler or witnessed byRuiz Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTodd Road
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Todd Road
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSource
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number1
Sublot number2 Aggregate Mix Number

Test Details

DIME Sample ID: 2025-10-24-69
DIME Test ID: 2025-10-24-69-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-04-03

Test Results


How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Jose Amparan Ruiz
Date of test: 10/29/2025
Clay reading: 8
Sand reading: 3.5
Sand Equivalent: 44
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/3/2026 ✔