Summary for Test 2025-10-22-85-1

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date10/22/2025 Sample Unique Key85
Date that the sample was received by the laboratory/organization performing the testing10/23/2025 Sample typeQuality Control
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes1 per batch
From where was the sample collectedJob Site First name of sampler or witnessed byErika
Last name of sampler or witnessed byEstrada Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons N.Hollywood
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1763194
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOS18-1 STA 2591+25 FSBT Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-10-22-85
DIME Test ID: 2025-10-22-85-1
Testing Lab: Sequoia Consultants
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-03-27

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ricardo Becerra
Date of test: 11/19/2025
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 121120 lb
Maximum load on cylinder 2: 121840 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4300 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/27/2026