Summary for Test 2026-03-23-39-1
Test performed: ASTM C136-19Project Information
| Project Identifiers | Project ID: 1001375 DEA: 040A53T4 EFIS: 0421000155 COOP: 040A53TCM |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-L1.8/L3.2 |
| Award Date | 06/20/2025 |
| Closeout Date | Not set |
| Work Description | Construct I-80 WB Truck Scales |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SOLANO COUNTY IN AND NEAR FAIRFIELD ON ROUTE 12 FROM THE 80/12 EAST JUNCTION TO 0.9 MILE EAST OF CHADBOURNE ROAD UNDERCROSSING AND ON ROUTE 80 FROM 0.5 MILE WEST OF DAN WILSON CREEK BRIDGE TO WEST TEXAS STREET UNDERCROSSI |
| QA Service Level | 1 (Verified on 07/10/2025) |
Sample Information
| Sample Taken Date | 03/23/2026 | Sample Unique Key | 39 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/19/2026 |
| Sample type | Quality Control | A brief description of the sample | WASH CONCRETE SAND |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Alejandro | Last name of sampler or witnessed by | Orozco |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Pinnacle Prestress, Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3928516 |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Vulcan San Emidio |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | On Site Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-03-23-39
DIME Test ID: 2026-03-23-39-1
Testing Lab: Pinnacle Prestress, Incorporated
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-03-27
Test Results
What type of gradation is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Has the fine aggregate sample been reduced? (question for combined gradation type): Yes
Input Type: Calculated
Tester's full name: Alejandro Orozco
Date of test: 03/23/2026
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 98 %
Cumulative percent passing the #8 sieve: 84 %
Cumulative percent passing the #16 sieve: 60 %
Cumulative percent passing the #30 sieve: 37 %
Cumulative percent passing the #50 sieve: 14 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/27/2026 ✔